Replace red light indicator for xTool F2 Ultra

Applicable scenario

Use this guide if the red light indicator on your F2 Ultra becomes dim or stops working.

Tools required

  • 2.5 mm hex screwdriver
  • 2 mm Phillips screwdriver
  • A new red light indicator

Safety first

Before replacing the red light indicator:

  1. Power off the machine.
  2. Unplug the power cable.
  3. Remove the safety key at the back of the machine.

Replacement steps

Step 1: Unscrew the mounting screws

Use the 2.5 mm hex screwdriver to unscrew the two screws securing the red light indicator.

Step 2: Remove the cover of the laser module

Follow the instructions from 00:00 to 01:09 of the video to remove the cover of the laser module.

Step 3: Remove the old red light indicator

Disconnect the connection cable and remove the old red light indicator.

Step 4: Install the new red light indicator

Insert the new module in the same orientation.

Note: Make sure the light-emitting end is close to the field lens. This is critical for proper alignment.

Step 5: Secure the screws

Tighten the two screws using the hex screwdriver.

Step 6: Connect the new red light indicator

Insert the connection cable for the new red light indicator to the laser module.

Step 7: Install the cover of the laser module back

Follow the instructions from 01:35 to 02:20 of the video to install the cover of the laser module back.

Step 8: Perform fiber IR and blue-light laser calibration

After replacement, enter Device settings > Parameter settings, and click Start calibration to perform a calibration to ensure accurate focusing.